HOME > Products > Back-End Semiconductor Equipment > Assembly & Bonding Equipment > Die Bonder >

Used ASMPT AD280 Plus High-Precision Die Bonder

Used ASMPT AD280 Plus automatic die bonder with published ±3 μm @ 3σ XY placement accuracy. Actual capability depends on the optics, calibration, material handling, tooling and installed process options.

Used ASMPT AD280 Plus High-Precision Die Bonder EQUIPMENT IMAGE
Configuration Review Model and installed options
New / Used Supply Subject to project availability
Global Delivery Destination-based assessment
Technical RFQ Package and process matching

The ASMPT AD280 Plus is an automatic high-precision die bonder with published XY placement accuracy of ±3 μm @ 3σ using look-through pattern recognition.

For a used AD280 Plus, that specification should be treated as a capability to verify rather than a result automatically transferred with the machine. Accuracy depends on the vision system, mechanical condition, calibration, tooling, material and test method.

The most useful evidence is not a startup video or a single successful placement. It is a recorded placement study using representative dies and substrates across a meaningful number of cycles.

ASMPT AD280 Plus High-Precision Die Bonder

What ±3 μm @ 3σ Really Means

The ±3 μm @ 3σ specification is a statistical placement result obtained under defined conditions. It should not be interpreted as a guaranteed maximum error for every die, substrate, process or used machine.

A useful accuracy report should identify:

  • The die and substrate used for testing

  • Face-up or flip-chip placement mode

  • Number of measured placements

  • Measurement method and measuring equipment

  • Mean X and Y placement offset

  • X and Y standard deviation or 3σ result

  • Die-rotation result when required

  • Machine warm-up and test duration

  • Results from different positions across the work area

A machine can show low repeatability variation while still carrying a consistent placement offset. Both centering and variation must therefore be reviewed.

Published Capability and Used-Machine Evidence

Published CapabilityWhat It MeansWhat Must Be Verified
±3 μm @ 3σ XY placementHigh-precision placement under specified conditionsMulti-cycle measurement using representative die and substrate material
Look-through pattern recognitionPatented optical alignment technologyCameras, lenses, lighting, optical cleanliness, calibration and recognition stability
Flip-chip handlingThe platform can support flipped-die placementInstalled flip mechanism, optics, software, bond tools and product-specific alignment
Wafer inputWafer on expander or clamp ring is the standard input formatWafer diameter, frame type, expander, ejector and wafer-map compatibility
Alternative die inputsWaffle pack, Gel-Pak, tray and tape feeder are available configurationsConfirm which physical handlers and software functions are installed
Material traceabilityBarcode, 2D code or OCR can be used on substrate, wafer or dieReader hardware, camera, software license, code format and factory-system interface
Machine dimensionsApproximately 2,150 × 1,400 × 2,300 mmConfirm the actual unit, auxiliary modules, service clearance and shipping fixtures

When a Used AD280 Plus Makes Sense

The AD280 Plus is easier to justify when the product genuinely needs approximately ±3 μm placement and the available machine contains the required material-handling and process options.

  • Die or optical-component placement with tight XY tolerance

  • Flip-chip placement using compatible dies and substrates

  • Products requiring alignment through look-through pattern recognition

  • Multiple die-input formats when the corresponding handlers are installed

  • UV adhesive processes when curing hardware is installed

  • Products requiring controlled bond force when the sensor option is installed

  • Traceability projects using compatible barcode, 2D-code or OCR functions

It may be an unnecessarily expensive or complex choice when the product only requires conventional leadframe die attach at a much wider placement tolerance.

For high-volume 12-inch wafer-to-leadframe epoxy production, the ASMPT AD8312Plus may be a more relevant platform. If the priority is rapid repetitive placement of small dies rather than several-micron alignment, the ASM AD50Pro should be evaluated separately.

Look-Through Optics Are Central to the Machine’s Value

The AD280 Plus should not be evaluated only as a mechanical pick-and-place system. Its high-precision positioning depends heavily on the complete optical chain.

The inspection should cover:

  • Upper and lower cameras

  • Lenses and look-through optical components

  • Lighting channels and intensity stability

  • Optical contamination, scratches or haze

  • Camera mounting and mechanical stability

  • Pattern-recognition software and licenses

  • Calibration plates, targets and procedures

  • Recognition performance on the intended die and substrate

A clear camera image is not sufficient evidence. The system must repeatedly calculate and correct the relative die-to-substrate position during actual placement.

Flip-Chip Capability Must Be Demonstrated Separately

ASMPT identifies flip-chip handling as a platform capability, but this does not mean every used AD280 Plus is ready for every flip-chip product.

The available machine should be checked for:

  • Installed die-flipping mechanism

  • Die-side and substrate-side recognition

  • Compatible bond head and collet

  • Bump or pad visibility under the installed lighting

  • Substrate fixture and planarity

  • Parallelism and placement-height setup

  • Bond-force requirements

  • Installed adhesive, flux or curing components when required

A face-up placement test does not prove flip-chip capability. The flipped die must be aligned and placed onto representative substrate features.

Optional Functions Must Not Be Presented as Standard

OptionWhy It MattersEvidence Required
Bond-force sensorProvides controlled and monitored placement forceSensor hardware, controller support, calibration and force-response test
Snap UV curingSupports spot or panel UV curing for compatible adhesivesUV source, optics, power measurement, exposure control and safety interlocks
Waffle-pack inputAllows dies to be supplied outside a wafer frameHandler, tray format, pickup coordinates and software support
Gel-Pak inputSupports compatible Gel-Pak die presentationInstalled holder, pickup setup and supported Gel-Pak dimensions
Tray or tape feederAdds alternative component-input formatsPhysical feeder, interface, indexing and software configuration
Barcode, 2D code or OCRSupports material and product traceabilityReader hardware, recognition test, software license and data export

If an option is physically installed but cannot be calibrated or operated, it should be listed as untested rather than included as a confirmed machine capability.

How to Verify High-Precision Placement

A practical acceptance test should run after the machine reaches a stable operating condition. Representative dies and substrates should be placed at multiple positions rather than repeatedly using only the center of the work area.

  1. Confirm machine leveling, environmental conditions and calibration status.

  2. Load the intended or technically comparable die and substrate.

  3. Use the required face-up or flip-chip configuration.

  4. Run sufficient consecutive placements to produce meaningful measurement data.

  5. Measure X position, Y position and rotation using calibrated equipment.

  6. Review mean offset, variation and results across different work-area positions.

  7. Repeat after sustained operation to identify thermal drift.

  8. Record rejected placements, recognition failures and operator intervention.

The published ±3 μm figure should only be repeated as an actual machine result when the test conditions and measurement report support it.

Information Required for the Available AD280 Plus

Machine IdentityModel, nameplate, serial number and manufacturing year
Previous ApplicationOriginal die, substrate and bonding process when available
Vision SystemCameras, lenses, lighting, look-through optics and calibration accessories
Material InputWafer, Waffle Pack, Gel-Pak, tray or tape-feeder configuration
Bond HeadHead type, collets, force sensor and associated tooling
Flip-Chip SetupFlip mechanism, recognition functions, tools and completed testing
UV CuringSpot or panel curing hardware, UV source condition and controls
TraceabilityBarcode, 2D-code or OCR hardware and enabled software
SoftwareVersion, licenses, machine backup and available process programs
Test EvidencePower-on, functional, process and measured placement results stated separately

Used ASMPT AD280 Plus Availability

Price and suitability depend heavily on the installed optics, material handlers, flip-chip hardware, bond-force sensor, UV curing, traceability functions, tooling and completed accuracy test.

  • Availability: Confirm against the physical machine

  • Condition: State whether it is as-is, function-tested or process-tested

  • Configuration: Provide an itemized list of standard and optional modules

  • Accuracy: Supply measured results when representative testing is available

  • Price: Quote according to the actual configuration and test scope

  • Export: International packing and shipment can be arranged

Send the die dimensions, substrate drawing, required placement accuracy, material-input format, face-up or flip-chip process, bond-force requirement, UV-curing requirement and destination through our equipment inquiry form.